In a room filled with fresh air, it is easier to breathe, work more productively and sleep better. But opening a window for airing every 2-3 hours is problematic, do you agree? Especially at night, when all family members sleep sweetly.
One of the automated solutions for this task is the supply and exhaust ventilation (PVV) of the room. But how to make it right? We will help you learn the principle of work and deal with the features of the arrangement.
In our article, the constituent elements of the supply and exhaust system, the rules for their calculation and the norms of air exchange in rooms of various types are considered.
Schemes of arrangement of ventilation are selected, a photo depicting individual elements of the system, useful video recommendations are given for the installation of a ventilation system in a private house with their own hands.
What is ventilation?
How often do we air a room? The answer should be as honest as possible: 1-2 times a day, if you do not forget to open the window. How many times at night? A rhetorical question.
According to sanitary and hygienic standards, the total air mass in the room where people are constantly must be completely renewed every 2 hours.
Under the usual ventilation understand the process of exchange of air masses between a confined space and the environment. This molecular kinetic process provides the ability to remove excess heat and moisture using a filtration system.
Ventilation also ensures that indoor air meets sanitary and hygienic requirements, which imposes its own technological limitations on the equipment that will generate this process.
Image Gallery
Photo from
The supply and exhaust ventilation system is designed to implement air exchange measures, the result of which ensures sanitary and hygienic standards in the room
Actions that ensure both fresh air flow and exhaust air mass removal are needed mainly where intensive air exchange is required.
In systems of the supply and exhaust type, devices are combined that stimulate either air exhaust, or its inflow, or forcing and sucking air simultaneously
All supply and exhaust ventilation structures belong to the mechanical category, which requires the installation of technical devices and the use of electricity
The ventilation systems of the supply and exhaust type can carry out filtering, irrigation, heating or cooling of the air. But much better deal with the processing of air flow air conditioners, which are often used as additional climate equipment
Air ducts and equipment for ventilation systems only in industrial buildings are laid in an open way. In commercial and residential premises, they are hidden in attics or behind suspended ceilings, with the exception of loft
Traditionally, air ducts were assembled from elements in the manufacture of which galvanized steel was used. To this day, tin is used in enterprises and in buildings intended for public visits.
Ventilation ducts in private kitchens, country houses and in the premises of enterprises that do not require the installation of powerful systems are constructed from rigid, plastic and corrugated polymer pipes
Ventilation ducts
Inflow and exhaust device
Supply and exhaust circuits in industrial premises
Mounted ventilation ducts under the ceiling
Ventilation operation in tandem with air conditioning
Location of ventilation systems
Tin ventilation duct assembly
Polymer ventilation ducts and corrugation
Ventilation subsystem - a set of technological devices and mechanisms for intake, removal, movement and purification of air. It is part of an integrated communications system for premises and buildings.
We recommend that you do not compare the concepts of ventilation and air conditioning - very similar categories that have a number of differences.
- Main idea. Air conditioning provides support for certain parameters of air in a confined space, namely temperature, humidity, degree of ionization of particles and the like. Ventilation also makes a controlled replacement of the entire volume of air through the inflow and exhaust.
- Main feature. The air conditioning system works with the air that is in the room and the influx of fresh air itself may be completely absent. The ventilation system always works on the border of a confined space and the environment through exchange.
- Means and methods. In contrast to simplified ventilation, air conditioning is a modular scheme of several units, which processes a small part of the air and thus maintains the sanitary and hygienic parameters of the air in the specified range.
The ventilation system in the house can be expanded to any desired scale and provides, in case of emergency in the room, a fairly quick replacement of the entire volume of air mass. What happens with the help of powerful fans, heaters, filters and an extensive piping system.
You may be interested in information on the arrangement of a ventilation duct made of plastic ducts, which is discussed in our other article.
In addition to the main function, ventilation systems can be part of an industrial-style interior, which is used for office and retail premises, entertainment venues
There are several classes of ventilation that can be divided with respect to the method of generating pressure, distribution, architecture and purpose.
Artificial air injection in the system is carried out using blower units - fans, blowers. By increasing the pressure in the piping system, you can move the air-gas mixture over long distances and in a significant volume.
This is typical for industrial facilities, industrial premises and public facilities with a central ventilation system.
The generation of air pressure in the system can be of several types: artificial, natural or combined. The combined method is often used.
Consider ventilation systems local (local) and central. Local ventilation systems are “targeted” narrowly targeted solutions for specific rooms where strict compliance with standards is required.
Central ventilation provides an opportunity to create a regular air exchange for a significant number of identical premises.
And the last class of systems: supply, exhaust and combined. Supply and exhaust ventilation systems provide simultaneous inflow and exhaust of air in space. This is the most common subgroup of ventilation systems.
Such designs provide easy scaling and maintenance for a wide variety of industrial, office and residential buildings.
The physical basis of the ventilation system
The supply and exhaust ventilation system is a multifunctional complex of ultrafast processing of a gas-air mixture. Although this is a system of forced gas transportation, it is based on completely understandable physical processes.
To create the effect of natural convection of air flows, heat sources are placed as low as possible, and exhaust elements in the ceiling or under it
The word “ventilation” itself is closely related to the concept of convection. It is one of the key elements in moving air masses.
Convection is the phenomenon of circulation of thermal energy between cold and warm gas flows. There is natural and forced convection.
A bit of school physics to understand the essence of what is happening. The temperature in the room is determined by the temperature of the air. Carriers of thermal energy are molecules.
Air is a multi-molecular gas mixture that consists of nitrogen (78%), oxygen (21%) and other impurities (1%).
Being in a confined space (room), we have a heterogeneity of temperature with respect to height. This is due to the heterogeneity of the concentration of molecules.
Given the uniformity of gas pressure in a confined space (room), according to the basic equation of the molecular kinetic theory: pressure is proportional to the product of the concentration of molecules and their average temperature.
If the pressure is the same everywhere, then the product of the concentration of molecules and temperature in the upper part of the room will be equivalent to the same product of concentration and temperature:
p = nkT, ntop* Ttop= nbottom* Tbottom, ntop/ nbottom= Tbottom/ Ttop
The lower the temperature, the greater the concentration of molecules, and therefore the greater the total mass of the gas. Therefore, it is said that warm air is “lighter” and cold air is “heavier”.
Proper ventilation in combination with the convection effect is able to maintain the established temperature and humidity conditions during periods of automatic shutdown of the main heating
In connection with the foregoing, the basic principle of the arrangement of ventilation becomes clear: air supply (inflow) is usually equipped at the bottom of the room, and exhaust (exhaust) - at the top. This is an axiom that must be considered when designing a ventilation system.
Features of supply and exhaust ventilation
Supply and exhaust ventilation interacts with two different in composition and purpose air flows, which are subsequently processed.
In PVV, all the necessary equipment and additional systems are placed in a single frame, which can be installed inside the loggia, in the attic, on the wall outside the house, etc.
The special design of the installation provides ample opportunity to provide ventilation of almost any number of rooms in the building.
In addition to the main function of moving air, the supply and exhaust ventilation includes the following arsenal of auxiliary subsystems and additional functions.
Among which are the following:
- air cooling and heating;
- ionization and hydration of particles;
- disinfection and air filtration.
Consider a typical duty cycle of a supply and exhaust ventilation system, which is based on a two-circuit transportation model.
At the first stage, the intake of cold air from the environment and the extraction of warm air from the room. On both sides, the air goes through a cleaning system.
After that, cold air is transferred to the air heater (heater) - typical of the air supply with heat recovery. In addition, heat is transferred to cold gas from warm exhaust air - typical of conventional systems.
After heating and heat exchange, exhaust exhaust air is discharged through an external channel, and heated fresh air is supplied to the room.
A popular arrangement of the ventilation module includes a heat exchange chamber (recuperator), in which heat energy is exchanged between oncoming air flows. In any case, each stream passes through a dual filtration system.
The main principles of supply and exhaust ventilation are efficiency and economy.
The classical scheme of supply and exhaust ventilation has the following advantages:
- high degree of purification of the input stream
- affordable operation and maintenance of removable elements
- design integrity and modularity.
To expand the functionality, the supply and exhaust units are equipped with auxiliary control and monitoring units, filter systems, sensors, self-timers, silencers, signaling devices for overloading electric motors, recuperative units, condensate pallets, etc.
Image Gallery
Photo from
Supply unit on the facade of the house
Blocks with filters and heaters
Forced-air and exhaust installation
Exhaust installation in car service
Dynamic ventilation parameters
A lot of questions are associated with the design of a ventilation system, because in the case of an erroneous calculation of characteristics from a completely economical ventilation complex, you can get a wasteful “monster” of energy resources.
Which directly affects the financial costs of its maintenance. As a result, the idea of economical operation of the equipment is not considered.
The main load of the ventilation system falls on the fan. Fan performance depends on the shape of the impeller (wheels with blades), the quality of materials and the assembly of equipment
In order to correctly design the supply and exhaust ventilation, it is recommended to perform algebraic calculations of the unit's performance and dynamic parameters of air flows.
There are several different calculation methods and algorithms, but one of the simplest and most reliable options will be presented to our attention.
All that is associated with secondary processes of hydration, additional ionization and secondary purification at this stage can be ignored.
Settlement Standards
To give a complete list of sanitary norms and rules (SNiP) that are put forward to various ventilation systems is irrational, since there is enough material for a couple of books, but it is necessary to know the reference constants for residential and office premises.
As for office premises, when building a ventilation system, the main attention is paid to those rooms where the office personnel will be located.
Further, all standards are indicated per person. In a classic office building on one floor there is a complete set of premises for various purposes.
For example, in an office in one hour, 60 cubic meters of air should be replaced, in operating rooms - 30-40 m3, in the bathroom - 70 m3, in the smoking room - more than 100 m3, in the corridors and lobby - 10 m3.
According to the general sanitary standards for residential premises, in one hour there is a complete exchange of air mass in the amount of 30 m3 per person - based on the number of residents.
There is another approach to calculating air volume - by area. 3 m per square meter of living space3.
Separately, it is worth mentioning the ventilation of industrial facilities and warehouse hangars - 20 m3 per unit area. In such huge rooms, ventilation systems are built on the basis of a multi-component system of twin fans (4, 8, 16 or more pcs in a frame)
For the remaining utility rooms, there are ready-made regulatory parameters. So, a kitchen with an electric stove - more than 60 m3, with a gas stove - more than 80 m3, bathroom - at least 25 m3 etc.
In addition, it must be remembered that for living rooms the air flow rate is not more than 2 m / s, and for the kitchen and bathroom the speed should be 4-6 m / s.
Formulas and explanations to them
We pass directly to the characteristics and formulas. The calculations take place in several stages, at each of which we calculate one of the characteristics of the ventilation system.
Air displacement
Consider the calculation of the working volume of air (m3/ h).
For the office, we recommend making a calculation according to the number of people:
V = 35 * N,
Where N - the number of people simultaneously in the room.
For apartments and private houses, it is necessary to make a miscalculation regarding the volume of living space:
V = 2 * S * H,
Where: 2 - the coefficient of the multiplicity of air exchange per unit time (for 1 hour); S - living space; H - the height of the premises.
The calculation of the cross section of the duct
Ventilation duct cross-section is calculated in cm2. The main ducts are of two types in cross section: round and rectangular.
The cross-sectional area of the pipe is calculated by the ratio:
Scut= V * 2.8 / ω,
Where: Scut - cross-sectional area; V - air volume (m3/ h); 2,8 - coefficient of coordination of dimensions; ω - flow rate in the highway (m / s).
The flow rate of air passing through the highway is usually equivalent to 2-3 m / s.
By calculating the cross-sectional area of the duct, you can determine the diameter for a round or the width / height for a rectangular duct. Knowing the width, we can find the height of the section and vice versa. The diameter of the circular section will be √4 * Scut/ pi
Number and size of diffusers
Let us further consider how to calculate the number and size of diffusers. Sprayer dimensions are usually chosen 1.5-2 times more than the cross-sectional area of the main line.
With the number of diffusers a little more complicated, they are calculated by the formula:
N = V / (2820 * ω * d2),
Where: N - the desired number of diffusers; V - air mass flow (m3/ h); ω - air flow rate (m / s); d - diameter of the diffuser (m), if it is round.
If the diffuser is rectangular, then:
N = π * V / (2820 * ω * 4 * a * b),
Where: π - Pi, a and b - dimensions of the section.
Installation Performance Options
Two of the most important characteristics of a ventilation unit are known - power and the degree of pressure generated. The power of the ventilation station is calculated as follows:
P = ΔT * V * Cv / 1000,
Where: ΔT - delta of inlet / outlet air temperatures (° С); V - air mass flow (m3/ h); Cv - heat capacity of air (0.336 W * h / m³ * ° С).
The generated pressure is determined by the characteristic curve of the performance of the main fan.
This parameter should be equivalent to the aerodynamic drag of the air network. Fan manufacturers provide a graph of the curve in the product data sheet.
In addition, it is important to have a general idea about the heater of the inlet air flow - the heater. This is a separate part of the ventilation system where air is heated. Passing, for example, through a heat sink, the air is thereby heated.
A heater in which heating occurs through a radiator and the exchange of thermal energy with an exhaust stream is called a recuperator. There are one and multi-section recuperators, which allow mixing air flows with a large difference in their input temperatures
In conclusion, it is worth mentioning the supply voltage for the ventilation unit. It is recommended to use a voltage network of 380 V, it will ensure reliable operation of the installation of any power.
Specifics of mechanical ventilation installation
With the installation of a ventilation unit of a supply type, the home master could no doubt manage without attracting workers.
However, it is worth remembering that the work is carried out at a dangerous height for an inexperienced performer. Therefore, it is better to attract those who have experience, tools and safety devices to perform the following steps:
Image Gallery
Photo from
Stage 1: A diamond drilling machine designed to form holes in concrete, masonry, brick, drill a hole with a diameter equal to the cross section of the duct
Stage 2: The drilled hole is cleaned of dust and small particles of the drilled structure, then an air duct is inserted into it
Stage 3: the unit housing is separated from the system unit to facilitate work
Step 4: The system unit is temporarily removed to the side, the case is checked for strength of the joints so that they do not have to be adjusted at height
Stage 5: The safety rope, to which the body will be attached, is inserted into the duct and thrown out the window
Stage 7: The second part of the safety housing, mounted on the housing, is carried out into the duct from the street
Stage 7: Carefully holding and insuring with a rope, the body is connected to the duct
Step 8: Carefully unrolling the case and directing it to the window, bring the system unit into the case and snap it
Drilling holes in the wall for channel entry
Air duct installation
Supply unit enclosure
Preparing the housing for installation
Safety rope fixing
Cable mount for housing mounting
Installation of the housing at the location
Joining the system unit
Upon completion of completely difficult manipulations on the installation of the direct air-supply unit, it remains only to connect it to the communications.
Let us consider this process in more detail using the following photo selection.
Image Gallery
Photo from
Drilling cable outlet holes
Connecting power and control wires
Bracket Mount for Diffuser
Installing and fixing the diffuser
Installation of control panels
The appearance of the supply unit
Two-room wiring option
Installation scheme on an insulated loggia
Information about the installation sequence of forced ventilation units will help to avoid many of the grossest errors made by inexperienced installers.
Features of the construction of natural PVV
When developing high-quality natural supply and exhaust ventilation, most specialists observe a certain “charter” of design and installation works.
These rules help create truly effective and economical solutions even for the most non-standard layouts of rooms and utility rooms in a private house and multi-room apartment of a high-rise building.
During the design of ventilation, you must try to create a natural flow of air from the living rooms through the corridors to the bathroom and kitchen
Corridors in this case act as flowing spaces. Therefore, the main ventilation unit of the system must be located in the center of the house, in the upper part of the corridors or utility rooms.
For example, the ventilation module for a 2-story private house can be located on the ground floor at the top of the utility room or the main corridor. For a 1-storey building, as an option, in the lower part of the attic.
When laying the main pipeline, you need to remember that the supply air must go into the living rooms, and the exhaust air must go through the kitchens and utility rooms.
Therefore, the supply air diffusers are located on the conditional boundary “room-environment”, and the hoods in the kitchen, in the bathroom, utility room, toilet.
The diffuser combines two functions: even distribution of fresh air and the removal of already used air. They come in all shapes. Made of sheet metal and plastic
There are comments regarding the height of the location of the inlet and outlet air openings. The outlet of the ventilation system is placed necessarily above the roof level of the building.
This will protect the air intake from the secondary intake of fresh air through the exhaust openings.
Fresh air must be taken at a height of at least 2 meters from the surface of the earth.
Because small abrasive particles and dust can rise with the help of wind flows to a height of more than 1 meter and fly into the supply air diffusers, thereby quickly clogging the primary filters.
The video tells and demonstrates the features of the design and installation of PVC in a private house:
Another illustrative example of a turnkey solution for ventilation of a private 1-story wooden house:
Summarizing the above information, we note that the supply and exhaust ventilation is simple for design, available for purchase and installation of the system.
Ventilation in conjunction with the heating system allows you to organize a balance of fresh and warm air in the room.
Did you arrange ventilation in the country? Or do you know the secrets of designing and installing a ventilation system in an apartment? Please share your experience - leave your comments on this article.