Private houses built taking into account modern projects, as a rule, are equipped with a sewage system. This system is designed to play an important role - to radically improve the sanitary and epidemiological situation inside the premises. However, in the framework of the implementation of such projects, it is also desirable ventilation of the sewage system in a private house.
It is projects with the ventilation of sewage systems that guarantee the full comfort of the home and contribute to the normal operation of the lines of domestic sewage. What ventilation schemes are most effective and how to implement them in a private house - this is what we will talk about in our article.
We also analyze the installation features of the constituent elements of sewer ventilation, paying attention to the norms and rules that must be observed at the same time.
Private House Sewerage Device
Private residential buildings, unlike municipal housing, have individual characteristics. Therefore, the sewerage scheme of a private house is not always possible to compare with standard municipal projects. You can only borrow individual solutions.
City municipal real estate is necessarily equipped with internal sewerage with ventilation. Private housing projects often preclude such an approach.
As a result, an important function of the operation of the sewerage is disrupted - blocking the exit of sewer fumes to the interior of the premises.
Whenever possible, they try to implement modern housing projects in the private sector with the connection of domestic sewage to a centralized highway. Autonomous schemes, however, are predominant in private homes.
The issue of ventilation of sewer networks is considered, as a rule, in relation to internal communications. This includes all sewage lines mounted directly inside buildings.
Moreover, based on the classification of collected runoff water, sewer systems are divided into three types:
- household (economic and fecal);
- rain (storm);
- production (industrial).
Household economic and fecal communications, in turn, are divided into centralized and autonomous systems. Many private house projects have been completed and are being carried out under an autonomous type.
True, at the present stage of the construction of private residential real estate, its owners are increasingly trying to connect home sewers to centralized lines. We recommend that you familiarize yourself with all the schemes of local sewerage of a country house, popular among users.
Domestic utilities traditionally contain the following plumbing fixtures:
- sinks and bathtubs;
- toilet bowls, urinals and bidets;
- shower cabins.
This whole set is united by a piping system, which also includes ventilation risers, manifolds, pipelines, check valves and other components designed to ensure the full functionality of the internal sewage system.
Image Gallery
Photo from
Private house sewer ventilation
Water Pollution Outlet
Conclusion of the fan pipe to the outside
Air intake through inspection hatch
Ventilation riser device inside the house
Sewer pipe on the facade of the house
Separate ventilation pipe in a private area
Ventilation of soil treatment systems
Why do we need sewage ventilation?
According to existing building regulations, low-rise (up to 2 floors) private real estate can be operated without equipping the sewage system with a fan pipe.
This tolerance is due to a small number of people (consumers) living in small private houses, which means a relatively low load on the plumbing.
This is how the end part of the construction of the fan pipe looks outside the roof of a residential building. The main riser usually ends at the level of the attic and connects to the end part using a corrugated tube of the appropriate diameter
A fan pipe is a structure assembled from standard plumbing pipes and installed as a vertical riser with access to a level above the roof horizon. The purpose of such a structure is to create a connection (ventilation) between the internal atmosphere of sewer communications and the atmosphere of the external environment.
Thanks to this connection, the pressure difference that occurs during the discharge of a large mass of wastewater is compensated. In addition, the ventilation riser eliminates the formation of gas stagnation in the line.
The need to withdraw the ventilation riser becomes apparent if the calculations show that the simultaneous flow from several plumbing fixtures can block the cross section of the main sewer pipe.
This situation leads to a “breakdown” of hydraulic locks (entrainment of water from siphons of sinks, bathtubs, etc.). As a result, unpleasant odors begin to penetrate into the room through the vacant space.
True, for the restoration of hydraulic locks, it is enough for a short time to turn on the spill of water on plumbing fixtures.
The standard layout of the sewer system in a private two-story house with a ventilation riser. Typically used in private housing projects designed to build two or more floors
Such a development of events usually does not threaten the communications of a small private house. Nevertheless, it is recommended not to abandon the construction of sewer ventilation for greater reliability and peace of mind for personal comfort.
The introduction of a fan pipe in the sewer circuit eliminates the “breakdown” of hydraulic locks, ensures a balance of air flows and ventilation inside the communications.
Mandatory use of ventilation riser:
- in private houses of more than two floors with the placement of toilets and baths on each floor;
- when the cross-sectional size of pipelines, branches and risers of the sewer line is less than 50 mm;
- The project of the house involves the installation of a septic tank in the surrounding area.
If the project of the house involves the placement of a swimming pool associated with a common sewage system, you will also have to take care of installing a riser.
Effective ventilation schemes
Consider the main options for arranging effective ventilation of the sewer system in a private home.
Option # 1 - installation of a fan pipe
The efficiency of ventilation of the sewage system is ensured by observing the two main principles of the installation of the fan pipe. The first principle is based on the difference in the diameters of the outlet and main pipes.
The diameter of the fan pipe should always be equal to or slightly larger than the diameter of the outlet from the main sewer line.
The second principle is to bring out and mount the output of the upper end part of the ventilation pipeline into the free air flow zone.
Installation of the ventilation riser always involves the use of pipes with a diameter equal to or greater than the diameter of the main sewer line line. The figure shows a variant of the transition from the tee of the sewage system to the fan pipe
The installation of the ventilation riser is traditionally carried out using standard plastic pipes with a diameter of 110 mm. In addition to plastic, cast-iron pipes are also used to assemble the fan line. But such a construction option, as a rule, is the prerogative of large projects.
Pipes are connected to one another using rubber seals. They fix the ventilation line to the wall of the house with metal clamps, laying them on the surface of the pipes through rubber gaskets.
Ventilation risers lead from the interface with the sewer, with subsequent passage through all floors of a private house, including the attic. The conclusion of the end part is carried out beyond the boundaries of the roof of the building
The upper point of the vented ventilation pipe should be above the roofing horizon of at least 300 - 700 mm. These values are recommended for installation on houses with flat roofs or where the roof is made under a slight slope. The steeper the roof slope, the higher the height of the end part of the ventilation pipe.
Building codes also provide for maintaining a height distance from the top of closely spaced windows to the top of the fan pipe.
Here it is recommended to adhere to parameters not less than values equal to 3.5 - 4 m. Ventilation of the home sewage system is mounted as a separate communications node.
Rules (SNiP) do not allow combining sewer ventilation lines with other technical systems (chimneys, air exhausts, etc.).
In developing a project for the construction of ventilation of an independent sewage system in a country house, the following requirements must be taken into account:
Image Gallery
Photo from
The ventilation riser of the autonomous sewage is discharged through a non-residential attic or through a complex shaft in which each channel is laid separately
Laying the ventilation riser of the sewer system in a cold attic is allowed if it is well ventilated and not used for domestic purposes
The height of the exhaust section of the ventilation pipe above a flat roof that is not equipped for operation should be at least 0.3 m above the roof covering
Above the pitched roof of a pitched roof, the ventilation pipe must rise at least 0.5 m
The riser of the venting system that discharges sewer gases on an operated flat roof should be 2.5 - 3.0 m high
If it is planned to remove sewer ventilation through the wall, then it is better to do this from the side that does not have door and window openings. If this is not possible, then between the sewer ventilation and the window horizontally should be at least 4 m
In two- and three-story country houses, the ventilation riser is equipped with a cleaning device, arranged at the level of plumbing, installed above all appliances
In country houses in recent years, bulky ventilation risers are increasingly replaced by ventilation valves. Their use simplifies the system and reduces the cost of its construction
Prefabricated ventilation shaft at home
Laying a fan riser in a cold attic
The height of the ventilation riser above the flat roof
Sloping roof ventilation pipe
Operated roof ventilation shaft
Fixing the ventilation pipe outside on the wall
Vent riser cleaning
Vent valve instead of a riser in a private house
We have detailed instructions on the site with step-by-step photos on installing a fan pipe.
Option # 2 - fan pipe + end pipe
For projects of private houses, it is sometimes permissible to introduce a scheme for installing a ventilation sewer riser, in which the upper section of the pipeline remains in the area of the attic.
But in this version, the attic should have the design of an actively ventilated room, which is rare for private housing projects. Therefore, the scheme with pulling the sewer ventilation pipe through the roof of the building remains relevant.
This is one of the most popular and common schemes for installing the end of the line for sewer ventilation. Easy and simple implementation of the solution thanks to the use of an elastic adapter
The conclusion through the roof is usually implemented according to the following plan:
- Vent riser finish in the attic.
- An end pipe is installed on the roof.
- Corrugate the upper section of the riser with the lower section of the trailer.
It is convenient and simple to install the end pipe on the roof using an elastic polymer adapter. This durable durable element has a round shape (there are also square ones), and due to the stepwise change in the diameter of the passage, it is easy to fit it to a pipe of a particular section.
It is only necessary to cut off the excess part of the adapter material along the line of the required diameter.
The end pipe, equipped with an adapter, is inserted into the passage hole previously made in the calculated place of the roofing. The lower cuff of the elastic adapter over the entire circumference of its abutment is treated with sealant.
Then, using a metal flange and screws, the cuff is tightly fastened to the roof surface.
In order to enhance the efficiency of natural traction, a deflector is additionally placed on the upper end part of the fan riser.
Ventilating deflector - a device that can enhance air draft due to the pronounced aerodynamic properties of the structure. The principle of operation of such devices is based on the Bernoulli effect, when the velocity of air masses is directly proportional to the change in the cross section of the channel.
For sewer ventilation schemes of private houses, static (fixed) deflectors are often used. Less commonly, but also rotary (rotating) deflectors are used.
This seemingly simple device plays a significant role in the ventilation of a home sewage system. According to various estimates, the deflector gives an increase in traction gain by 20-30%.
Option # 3 - sewer hood device
If the sewer outlet is not equipped with a water lock or the action of the specified useful device is not enough, it is worth constructing and installing a sewer hood:
Image Gallery
Photo from
Step 1: Drilling a hole to enter the street
Step 2: Install a ventilation tee
Step 3: Install the Plastic Elbow
Step 4: Drilling holes for retaining clamps
Step 7: Install Hose Clamps
Step 6: Processing Seals in a Silicone Joint
Step 7: Assembling the exhaust pipe on the wall
Step 8: Pipe bypass device in the overhang area
Option # 4 - installation of aeration (vacuum) valve
The use of vacuum (aeration) valves as an alternative to a fan pipe should be considered a purely conditional phenomenon. The scheme with vacuum valves, the owners of private real estate can only apply if it is completely impossible to install a ventilation riser.
The low reliability of aeration valves is confirmed even by the absence of any information on these devices in the SNiP documentation.
Double aeration valve for the section of the sewer pipe 110 mm. Under the twisted head of one of the parts, a simple structure based on a rubber-plastic membrane was found
Vacuum valves are used exclusively on sewerage systems of private small-format houses.
Simple valve device:
- plastic round case;
- in the body a through hole for the valve;
- membrane, rubber gasket.
The principle of operation of the device is also simple. If a discharged atmosphere (vacuum) is created in the sewer pipe due to an imbalance in the pressure balance, the valve opens and air from the room is sucked into the pipe. As soon as the pressure in the pipe is equalized, the valve returns to its place.
If desired, the aeration mechanism can be done independently. But there are factory products on sale that have running sections of 50 and 110 mm. They are not cheap, but more reliable.
Aeration valves are usually installed in the immediate vicinity of plumbing risers at the upper points of the sewer system. Most often, the installation of the valve is done on the upper branch of the tee (cross), which is mounted on the drain line from the toilet.
Owners of private houses who have opted for aeration valves will have to periodically engage in the maintenance of these plumbing fixtures.
A certain period of operation of vacuum valves is accompanied by the accumulation of deposits and contaminants in the place where the valve seal is located.
The tightness of the device is broken, the smells of sewers begin to penetrate into the room. Therefore, from time to time, maintenance is necessary, and here is another plus in favor of the first ventilation scheme.
This is how the installation of the aeration valve on the riser looks, which will be located next to the toilet in the toilet of a private house. This is one of the common applications, showing a very effective action.
Another disadvantage of simplified valve ventilation of a domestic sewage system is that it is functional only at positive temperatures. That is, if the aeration valve is installed in the area of a possible decrease in temperature to zero degrees or lower, there is a risk of a malfunction of the system.
On our website there is a detailed instruction for installing a vacuum valve in the sewer.
Option # 5 - outdoor sewage ventilation device
Often there is information about the schemes of external ventilation of the sewage system of private houses. The principle of building external ventilation is indicated almost the same as in the case of the internal circuit.
The fan riser for ventilation is mounted against the wall of the house and rises above the roof. Meanwhile, SNiP on this subject do not give any recommendations.
On the contrary, the documentation clearly states that fan risers for ventilation of household sewers should be built inside heated rooms.
Assembling a makeshift fan pipe deflector
It is not necessary to buy a ventilation deflector. This thrust pumping mechanism is quite capable of being done independently.
From the tool kit and material you will need the following:
- galvanized metal sheet;
- fasteners (small bolts with nuts or rivets);
- scissors for metal;
- pencil, ruler.
First of all, the lower part of the device is marked - a cone-shaped bell. At the bottom, its diameter should correspond to the diameter of the ventilation riser, and the diameter of the upper part is increased by 10-15% of the lower size.
The self-made deflector made under the sewer ventilation pipe of a private house looks like this. Minimum tool and material and almost the same performance as factory models
The resulting cone is fastened with bolts or rivets, a “skirt” is placed in the middle part, cutting off part of the air flow. An umbrella is attached to the top of the racks.
You can learn more about the location and meaning of the fan riser from the following video:
A comfortable home environment is the main factor that encourages owners of private residential buildings to pay attention to standard sewage ventilation technology.
Apply this method or be content with a simplified ventilation scheme - decide directly to the homeowners. Extra plans for the construction of "fly out" a pretty penny. True, you always have to pay for comfort.
Have you thought about installing a ventilation riser for the sewer system of your house? Maybe you still have unclear questions after reading our article? Ask for advice - our engineer will try to help you.
Or are you already using your own simple sewer ventilation? Tell us which scheme you applied, what difficulties you encountered in the design, and are you satisfied with the effectiveness of the riser? Leave your comments, add a photo in the block under this article.